Inbio260 can only support one FR1200? How to set the 485 address of FR1200?
Inbio260 can at most support four FR1200, two as in, two as out. There are six DIP terminals , 1-4 is for RS485 address , 5 is reserved , 6 is for extending the length of RS485. Set the odd number is for enter reader, and the even number is for exit reader(for example , two readers for one door- the rs485 address 1 is for enter door, rs485 address 2 is for out door ) And both 1 and 2 should be translate into the binary digits.
How to reset the device to the factory setting?
The number7 digit is off by default. When it is moved upwards and downwards for three times within 10 seconds and finally returned to OFF position, the factory settings will be restored after the access control panel is restarted.
The number 7 is used to restore to the factory setting, which kind of data will be initialed? Including the parameters setting?
If you forget the device IP or the device can not work normally, You can use the number 7 terminal to restore inbio460 to factory Setting , the configuration include device IP , communication password ,gateway ,subnet mask. The device IP will be 192.168.1.201,the communication password will be blank. And the parameters setting will not be changed, will stay at the device.
How to cancel the event records in the inbio?
The event records can not be cleared; when it reaches 100,000, it will overlap the before ones.
Inbio+FR1200,can FR1200 be used to register users?
FR1200 can not be used to register fingerprint, it can only be used for verification. Fingerprint sensor such as ZK4000,ZK4500 can be used to register users. The ZK4000 can be used only in 32 digits system; but ZK4500 can be used both in 32 digits and 64 digits.
which reader of the inbio controls which door?
About C3-200, the reader1 and reader3 are the in of lock 1 and lock 2; reader 2 and reader 4 are the out of lock 1 and lock 2. About C3-400, all of the readers are for the in of the lock. When C3-400 changes to two-door two-way, the reader 1 is for the in of lock 1, the reader 2 is for the out of lock 2; the reader 3 is for the in of lock 2, the reader 4 is for the out of lock 2. If for inbio, the odd number is for in of the lock, the even number is for out of the lock.
What is dry mode and wet mode ?
The control panel supports “dry mode” and “wet mode” by using the jumper. For “wet mode”, short 2-3 and 4-5 terminals. The control panel and the lock use the separate power supply. One is connected with +12V and GND of POWER interface (for the control panel), the other is connected with V+ and V- of LOCK interface (for the lock). The factory default jumping is set as dry mode.